Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
BMC Musculoskelet Disord ; 25(1): 202, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38454368

RESUMO

BACKGROUND: Posterior tibial slope (PTS) exhibits considerable variability among individuals and is anticipated to influence the accuracy of radiographic measurements related to the knee. Despite this potential impact, there is a lack of prior research investigating how PTS affects the accuracy of these measurements. Therefore, this study aimed to investigate the effect of PTS on the measurement reliability regarding the radiographic parameter of the knee. METHODS: The medical records of patients who took full-length anteroposterior radiographs of the lower limb between January 2020 and June 2022 were evaluated retrospectively. Radiographic parameters related to the knee joint characteristics such as osteoarthritis grade, hip-knee-ankle angle, weight-bearing line ratio, medial proximal tibial angle (MPTA), lateral distal femoral angle, joint-line convergence angle (JLCA), and PTS were measured. Subjects were classified into 3 groups according to PTS (group A, PTS < 4°; group B, PTS ≥ 4° and < 8°; group C, PTS ≥ 8°), and the measurement reliability for the radiographic variables was compared between groups. The intra- and inter-observer agreements were assessed using the kappa coefficients, intra-class correlation coefficients (ICC), and Bland-Altman plots. RESULTS: A total of 175 limbs (86 patients) were included in this study. As the intra- and inter-observer reliability for PTS ranged over 0.9, grouping was performed based on the average of the measured PTSs. The inter-observer reliability of the MPTA and JLCA decreased as the PTS increased (ICCs for MPTA in Groups A, B, and C: 0.889, 0.796, and 0.790, respectively; ICCs for JLCA in Groups A, B and C: 0.916, 0.859, and 0.843, respectively), whereas there were no remarkable differences in other variables. Similar trends were observed in the comparisons of intra-observer reliability and Bland-Altman plots also showed consistent results. CONCLUSION: The larger the PTS, the lower the measurement reliability regarding the radiographic parameters of the knee that includes the joint line, such as MPTA and JLCA. Given the occasional challenge in accurately identifying the knee joint line in patients with a relatively large PTS, careful measurement of radiographic parameters is crucial and utilizing repetitive measurements for verification may contribute to minimizing measurement errors.


Assuntos
Osteoartrite do Joelho , Tíbia , Humanos , Tíbia/diagnóstico por imagem , Estudos Retrospectivos , Reprodutibilidade dos Testes , Osteoartrite do Joelho/diagnóstico por imagem , Extremidade Inferior , Articulação do Joelho/diagnóstico por imagem
2.
Hip Pelvis ; 36(1): 62-69, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38420739

RESUMO

Purpose: To assess current practice in the treatment of osteoporosis in patients who underwent treatment for hip fracture in South Korea. Materials and Methods: A survey of 97 members of the Korean Hip Society, orthopedic hip surgeons who administer treatment for hip fractures in South Korea, was conducted. The survey was conducted for assessment of demographic data and perceptions regarding the management of osteoporosis in patients who have undergone treatment for hip fracture. Analysis of the data was performed using descriptive statistical methods. Results: The majority of participants were between the age of 41 and 50 years, and 74% were practicing in tertiary hospitals. Testing for serum vitamin D levels (82%) was the most commonly performed laboratory test. Calcium and vitamin D were prescribed for more than 80% of patients by 47% and 52% of participants, respectively. Denosumab was the most commonly used first-line treatment option for osteoporosis in hip fracture patients. Bisphosphonate was most often perceived as the cause of atypical femoral fractures, and the most appropriate time for reoperation was postoperative 12 months. Teriparatide was most preferred after cessation of bisphosphonate and only prescribing calcium and vitamin D was most common in high-risk patients for prevention of atypical femoral fracture. Conclusion: The results of this study that surveyed orthopedic hip surgeons showed that most participants followed the current strategy for management of osteoporosis. Because the end result of osteoporosis is a bone fracture, active involvement of orthopedic surgeons is important in treating this condition.

3.
Clin Orthop Surg ; 16(1): 73-85, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38304206

RESUMO

Background: Although many studies have been conducted on the association between the intercondylar notch size and the risk of anterior cruciate ligament (ACL) injury, few studies have examined its relationship with the condition after surgical treatment. Therefore, this study aimed to investigate the surgical outcomes of anatomical single-bundle ACL reconstruction according to intercondylar notch volumes. Methods: Medical records of patients who underwent anatomical single-bundle ACL reconstruction using a tibialis anterior allograft between 2015 and 2019 were retrospectively reviewed. For each sex, eligible patients were classified into two groups based on their percentile of intercondylar notch volumes, which were measured using postoperative three-dimensional computed tomography images (group S, ≤ 50th percentile of included patients; group L, > 50th percentile of included patients). Additional grouping was performed based on the group's percentiles of normalized values of intercondylar notch volumes to body heights. Between-group comparative analyses were performed on the perioperative data and surgical outcomes in both objective and subjective aspects. Results: One hundred patients were included in the study. For male patients, there were no differences in the overall surgical outcomes between groups, whereas group L showed a significantly greater knee anteroposterior (AP) laxity than group S at the final follow-up (p = 0.042 for the side-to-side differences [SSD] at the maximum manual force). Similarly, there were no differences in the female patients in the overall surgical results between the groups, whereas group L showed a significantly greater knee AP laxity at the final follow-up (p = 0.020 for the SSD at 134 N; p = 0.011 for the SSD at the maximum manual force). Additional analyses based on the normalized values of the intercondylar notch volume showed consistent results for male patients, and additional grouping for female patients was identical to the existing grouping. Conclusions: The surgical outcomes of anatomical single-bundle ACL reconstruction in patients with relatively small intercondylar notch volumes were comparable to those with large notch volumes, but rather showed favorable outcomes in postoperative knee AP laxity.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Humanos , Masculino , Feminino , Ligamento Cruzado Anterior/cirurgia , Estudos Retrospectivos , Fêmur/cirurgia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Resultado do Tratamento
4.
Sci Rep ; 13(1): 21422, 2023 12 05.
Artigo em Inglês | MEDLINE | ID: mdl-38049442

RESUMO

Femoral neck fracture is a common osteoporotic fracture in elderly patients and is effectively managed with arthroplasty. However, the benefits and risks of a surgical drain after arthroplasty in these patients are still debatable. Hence, we conducted this study to investigate the necessity of a surgical drain after hemiarthroplasty in elderly patients with femoral neck fracture. This study enrolled elderly patients (aged ≥ 70 years) who underwent cementless bipolar hemiarthroplasty for femoral neck fracture between April 2016 and December 2021. The patients were divided into two groups; the control group (199 patients) with a surgical drain after surgery performed between April 2016 and June 2020 and the study group (134 patients) with no surgical drain between July 2020 and December 2021. The demographics, perioperative data, and postoperative complications were compared between the two groups. Estimated blood loss, perioperative transfusion volume and rate, and length of hospital stay were significantly lower in the study group than in the control group (p < 0.001, p < 0.001, p = 0.008, and p < 0.001, respectively). Although there were no significant intergroup differences in the length of intensive care unit stay and in-hospital, 1-month, and 1-year mortalities, the incidence of postoperative medical complications was significantly lower in the study group than the control group (p = 0.001). A surgical drain may be unnecessary after hemiarthroplasty in elderly patients with femoral neck fracture considering less blood loss and transfusion, lower incidence of postoperative medical complications, and shorter hospital stay in the study group with no surgical drain.


Assuntos
Artroplastia de Quadril , Fraturas do Colo Femoral , Hemiartroplastia , Idoso , Humanos , Hemiartroplastia/efeitos adversos , Fraturas do Colo Femoral/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Tempo de Internação , Resultado do Tratamento , Estudos Retrospectivos
5.
Knee Surg Sports Traumatol Arthrosc ; 31(12): 5812-5822, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37938328

RESUMO

PURPOSE: To investigate the surgical outcomes of arthroscopic pull-out repair for medial meniscus root tear (MMRT) combined with the marrow stimulation procedures (MSP) for accompanying high-grade cartilage lesions. METHODS: Patients who underwent arthroscopic pull-out repair for MMRT between 2010 and 2019 were retrospectively reviewed. Patients who had at least 3 years of follow-up were included and classified into two groups according to whether MSP (microfracture or microdrilling) were performed on cartilage lesions in the medial tibiofemoral joint (group 1, patients with International Cartilage Repair Society [ICRS] grade 0-3a lesions and did not undergo MSP; group 2, patients with ICRS grade 3b-3d lesions and underwent MSP). Comparative analyses, including non-inferiority trials, were conducted between groups for subjective and objective outcomes. In addition, group 2 was further divided into two subgroups according to cartilage lesion size and compared with group 1 (group S, ≤ 2.0 cm2; group L, > 2.0 cm2). RESULTS: A total of 94 patients were included (group 1, 68 patients; group 2, 26 patients). There were no significant differences in clinical scores at postoperative 3 years and final follow-up between groups 1 and 2, but group 2 failed to satisfy the non-inferiority criteria compared to group 1 overall. In objective outcomes, group 2 did not meet the non-inferiority criteria for the rate of osteoarthritis progression compared to group 1, and it also showed a significantly higher proportion of high-grade osteoarthritis at final follow-up (P = 0.044) and a higher degree of osteoarthritis progression than group 1 (P = 0.03 for pre- to postoperative 3 years, and P = 0.006 for pre- to final follow-up). In additional evaluations comparing the subgroups of group 2 and group 1, group S showed relatively favourable results compared to group L in objective outcomes at final follow-up. CONCLUSION: Patients who underwent arthroscopic pull-out repair for MMRT combined with MSP for accompanying high-grade cartilage lesions showed suboptimal outcomes compared to those with no or low-grade lesions at mid-term follow-up. High-grade cartilage lesions ≤ 2.0 cm2 may be candidates for the surgical repair of MMRT if MSP are performed, but those with larger lesions may require alternative treatment strategies. LEVEL OF EVIDENCE: III.


Assuntos
Cartilagem Articular , Osteoartrite , Humanos , Meniscos Tibiais/cirurgia , Estudos Retrospectivos , Medula Óssea/patologia , Artroscopia/métodos , Osteoartrite/cirurgia , Ruptura/patologia , Cartilagem Articular/cirurgia , Cartilagem Articular/patologia , Resultado do Tratamento
6.
Hip Pelvis ; 35(3): 200-205, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37727294

RESUMO

Purpose: The aim of this study was to assess the current status of venous thromboembolism (VTE) prevention in Korean patients with hip fractures. Materials and Methods: A survey using a questionnaire on the experiences and protocols of VTE prevention was conducted among 570 members of the Korean Hip Society. Results: A total of 97 surgeons responded, with a response rate of 17.0%. Of the 97 participants, 61.9% answered that they had encountered one or more cases of symptomatic VTE in the past year. Mechanical prophylaxis was applied most often (30.9%) until the point of ambulation in standard-risk patients and most often (34.0%) extended until discharge in high-risk patients. Chemical prophylaxis was most often prescribed for a particular period of time rather than for recovery of walking ability (24.7% in standard-risk patients and 26.8% in high-risk patients). Dual prophylaxis was administered in the standard-risk group by 58.8% of the participants and in the high-risk group by 83.5%. Among the participants, 73.2% answered that they had been attentive to wound complications during chemical prophylaxis. More than half of the participants (59.8%) reported that they did not perform routine screening for VTE after surgery. Conclusion: The results of our survey provided information regarding the current status of VTE prevention for patients undergoing surgery for treatment of hip fractures in Korea as well as a baseline for establishment of educational programs and guidelines in the future.

7.
Hip Pelvis ; 35(3): 157-163, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37727295

RESUMO

Purpose: This study examined the methods for treatment of femoral neck fracture (FNF) preferred by members of the Korean Hip Society (KHS) and identified factors that influence decisions regarding the surgical intervention of choice. Materials and Methods: A total of 97 members of the KHS responded to the 16-question survey which included questions about the mean number of surgeries performed each month for treatment of femoral neck fractures, the cut-off age for deciding between internal fixation and arthroplasty, the implant used most often, usage of cement, and factors influencing each decision. Results: The mean cut-off age used when deciding between internal fixation and arthroplasty was 64 years old. Hemiarthroplasty (HA) (70%) was the most preferred option for treatment of displaced FNFs in cases where arthroplasty was indicated (total hip arthroplasty [THA] 19% and dual mobility THA 11%). The main reasons for selection of arthroplasty over reduction with internal fixation were age and pre-fracture ambulatory status. Pre-trauma ambulatory status and/or sports activity were the main factors in selection of HA over THA. Cement was used by 33% of responders. Poor bone quality and a broad femoral canal were factors that influenced the usage of cement. Conclusion: Management of FNFs in the elderly is a major health problem worldwide; thus, remaining alert to current trends in treatment is essential for surgeons. The mean cut-off age used in deciding between internal fixation and arthroplasty was 64 years old. HA is the preferred method for treatment of displaced FNFs for members of the KHS.

8.
Clin Orthop Surg ; 15(2): 182-191, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37008963

RESUMO

Background: This study aimed to compare the mechanical characteristics of four fixation methods including an anatomical suprapectineal quadrilateral surface (QLS) plate in hemipelvic models of anterior column-posterior hemitransverse acetabular fractures typical in elderly patients. Methods: In total, 24 composite hemipelvic models were used and allocated to four groups: group 1, pre-contoured anatomical suprapectineal QLS plate; group 2, suprapectineal reconstruction plate with two periarticular long screws; group 3, suprapectineal reconstruction plate with a buttress reconstruction plate; group 4, suprapectineal reconstruction plate with a buttress T-plate. Axial structural stiffness and displacement of each column fragment in four different fixation constructs were compared. Results: Multiple group comparisons of axial structural stiffness demonstrated significant difference (p = 0.001). Although there was no significant difference between groups 1 and 2 (p = 0.699), group 1 showed greater stiffness than groups 3 and 4 (p = 0.002 and 0.002, respectively). Group 1 showed less displacement in the anterior region of the anterior fragment than group 4 (p = 0.009) and in the posterior region than groups 3 and 4 (p = 0.015 and p = 0.015, respectively). However, group 1 demonstrated greater displacement than group 2 in the posterior region of the posterior fragment (p = 0.004), while showing similar displacement to groups 3 and 4. Conclusions: The anatomical suprapectineal QLS plate provided the mechanical stability comparable or superior to other existing fixations in osteoporotic models of anterior column-posterior hemitransverse acetabular fractures typical in the elderly. However, additional plate modification would be needed for better stability and outcomes.


Assuntos
Fraturas Ósseas , Fraturas do Quadril , Fraturas da Coluna Vertebral , Humanos , Idoso , Fraturas Ósseas/cirurgia , Fixação Interna de Fraturas/métodos , Acetábulo/cirurgia , Acetábulo/lesões , Parafusos Ósseos , Fenômenos Biomecânicos , Fraturas do Quadril/cirurgia , Placas Ósseas
10.
Arch Orthop Trauma Surg ; 143(4): 2027-2036, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35552802

RESUMO

INTRODUCTION: This study aimed to (1) evaluate the short-term clinical outcomes of patients who underwent non-operative treatment for partial anterior cruciate ligament (ACL) tears diagnosed using the outpatient-based diagnostic criteria and (2) investigate the radiographic predictors distinguishing patients at risk of non-operative treatment failure. METHODS: From 2010 to 2019, patients diagnosed with partial ACL tears and treated with non-operative treatment were reviewed retrospectively. Patients were then classified into two groups: those who successfully responded to non-operative treatment (group S) and those who failed to respond to non-operative treatment and required surgical reconstruction within 6 months after injury (group F). ACL laxity, patient-reported outcomes (PROs), and several radiographic parameters were analyzed. To identify radiographic predictors related to clinical outcomes, radiographic parameters were compared between the groups, which were statistically matched for potential confounders (age and activity level) using inverse probability of treatment weighting. RESULTS: A total of 44 patients were analyzed (mean age, 28.7 ± 8.7 years; 31 men), and classified into two groups (group S, 23 patients; group F, 21 patients). There were no significant differences in ACL laxity and PROs between the groups at 1 year after either non-operative treatment or surgical reconstruction. A comparison of radiographic parameters between the groups revealed significant differences in several parameters related to secondary signs of ACL injury. Subsequent regression analyses revealed that anterior tibial translation and extent of bone bruises were radiographic predictors related to clinical outcomes. CONCLUSION: Non-operative treatment for partial ACL tears diagnosed using the outpatient-based diagnostic criteria can provide successful short-term clinical outcomes in selective patients. Secondary signs of ACL injuries, particularly the amount of anterior tibial translation and the extent of bone bruises, are radiographic predictors that could differentiate patients at risk of non-operative treatment failure. LEVEL OF EVIDENCE: Retrospective cohort study, III.


Assuntos
Lesões do Ligamento Cruzado Anterior , Contusões , Masculino , Humanos , Adulto Jovem , Adulto , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/terapia , Estudos Retrospectivos , Pacientes Ambulatoriais , Tíbia , Contusões/complicações
11.
BMC Musculoskelet Disord ; 23(1): 1136, 2022 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-36577972

RESUMO

BACKGROUND: Conflicting results have been reported regarding the factors that can predict the discrepancy in the coronal alignment of the lower limb between radiographs taken in the standing and supine positions. Therefore, this study aimed to investigate factors that can predict discrepancies in the coronal alignment of the lower limb between radiographs taken in the standing and supine positions. METHODS: We retrospectively evaluated the medical records of patients who underwent full-length anteroposterior radiographs of the lower limb in both standing and supine positions between January 2019 and September 2021. The discrepancy in the coronal alignment of the lower limb between the standing and supine radiographs was defined as the absolute value of the difference in the hip-knee-ankle (HKA) angle between the two radiographs, which is presented as the ΔHKA angle. Correlation and regression analyses were performed to analyse the relationship among ΔHKA angle, demographic data, and several radiographic parameters. RESULTS: In total, 147 limbs (94 patients) were included in this study. The mean ΔHKA angle was 1.3 ± 1.1° (range, 0-6.5°). The ΔHKA angle was significantly correlated with body mass index and several radiographic parameters, including the HKA angle, joint line convergence angle, and osteoarthritis grade. Subsequent multiple linear regression analysis was performed using the radiographic parameters measured on the supine radiographs with the two separate models from the two observers, which revealed that body mass index and advanced osteoarthritis (Kellgren-Lawrence grades 3 and 4) had a positive correlation with the ΔHKA angle. CONCLUSIONS: Body mass index and advanced osteoarthritis affected the discrepancy in the coronal alignment of the lower limb between standing and supine radiographs. A discrepancy in the coronal alignment of the lower limb could be more prominent in patients with an increased body mass index and advanced osteoarthritis, corresponding to Kellgren-Lawrence grades 3 and 4.


Assuntos
Extremidade Inferior , Osteoartrite do Joelho , Humanos , Estudos Retrospectivos , Extremidade Inferior/diagnóstico por imagem , Radiografia , Articulação do Joelho , Osteoartrite do Joelho/diagnóstico por imagem , Tíbia/diagnóstico por imagem
12.
Sci Rep ; 12(1): 15221, 2022 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-36075997

RESUMO

Treatment of superomedially displaced acetabular fractures including a quadrilateral surface (QLS) is challenging. We present a surgical technique using an anatomical suprapectineal QLS plate through the modified Stoppa approach and report the availability of this plate to treat this fracture type along with the surgical outcomes. Sixteen consecutive patients (14 men and 2 women) who underwent surgical treatment using an anatomical suprapectineal QLS plate through a modified Stoppa approach for superomedially displaced acetabular fractures between June 2018 and June 2020, were enrolled retrospectively. These fractures included 11 both-column fractures and 5 anterior-column and posterior hemitransverse fractures, which were confirmed on preoperative 3-dimensional computed tomography. Surgical outcomes were clinically assessed using the Postel Merle d'Aubigné (PMA) score and visual analog scale (VAS) score at the final follow-up, and radiological evaluations were performed immediately after the operation and at the final follow-up. For comparative analysis, 23 patients who underwent internal fixation with the conventional reconstruction plate through modified ilioinguinal approach between February 2010 and May 2018, were selected. This control group was composed of 18 both-column fractures and 5 anterior-column and posterior hemitransverse fractures. The follow-up period was at least 1 year in all patients. The mean operation time and blood loss was 109 min, and 853 ml, respectively, whereas 236 min, and 1843 ml in control group. Anatomical reduction was achieved in 14 (87.5%) patients, while imperfect reduction was achieved in the remaining 2 patients. At the final follow-up, radiographic grades were excellent, fair, and poor in 14 patients (87.5%), one, and one, respectively. The mean PMA score was 16.1 (range 13-18) and the mean VAS score was 1.0 (range 0-3). No secondary reduction loss or implant loosening was observed. However, 2 patients underwent conversion to total hip arthroplasty (THA) due to post-traumatic arthritis and subsequent joint pain. No other complications were observed. In the comparative analysis, radiological outcome showed a significant relationship with the conversion to THA (p = 0.013). Shorter operation time and less blood loss were significantly observed in the QLS plate fixation group through the modified Stoppa approach compared with the conventional reconstruction plate fixation group through modified ilioinguinal approach (p < 0.001, respectively). Simultaneous reduction and fixation using an anatomical suprapectineal QLS plate through the modified Stoppa approach may be a viable technique in superomedially displaced acetabular fractures along with shorter operation time and less blood loss.


Assuntos
Fraturas Ósseas , Fraturas do Quadril , Lesões do Pescoço , Fraturas da Coluna Vertebral , Acetábulo/diagnóstico por imagem , Acetábulo/lesões , Acetábulo/cirurgia , Placas Ósseas , Feminino , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Fraturas do Quadril/cirurgia , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
13.
Bone Joint Res ; 11(3): 152-161, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35261280

RESUMO

AIMS: There are concerns regarding nail/medullary canal mismatch and initial stability after cephalomedullary nailing in unstable pertrochanteric fractures. This study aimed to investigate the effect of an additional anteroposterior blocking screw on fixation stability in unstable pertrochanteric fracture models with a nail/medullary canal mismatch after short cephalomedullary nail (CMN) fixation. METHODS: Eight finite element models (FEMs), comprising four different femoral diameters, with and without blocking screws, were constructed, and unstable intertrochanteric fractures fixed with short CMNs were reproduced in all FEMs. Micromotions of distal shaft fragment related to proximal fragment, and stress concentrations at the nail construct were measured. RESULTS: Micromotions in FEMs without a blocking screw significantly increased as nail/medullary canal mismatch increased, but were similar between FEMs with a blocking screw regardless of mismatch. Stress concentration at the nail construct was observed at the junction of the nail body and lag screw in all FEMs, and increased as nail/medullary canal mismatch increased, regardless of blocking screws. Mean stresses over regions of interest in FEMs with a blocking screw were much lower than regions of interest in those without. Mean stresses in FEMs with a blocking screw were lower than the yield strength, yet mean stresses in FEMs without blocking screws having 8 mm and 10 mm mismatch exceeded the yield strength. All mean stresses at distal locking screws were less than the yield strength. CONCLUSION: Using an additional anteroposterior blocking screw may be a simple and effective method to enhance fixation stability in unstable pertrochanteric fractures with a large nail/medullary canal mismatch due to osteoporosis.

14.
Injury ; 53(3): 1164-1168, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35034776

RESUMO

INTRODUCTION: Even though the dislocation rate is lower in the hemiarthroplasty (HA) than total hip arthroplasty, it has still developed as one of serious complications in elderly patients. We have used short external rotators (SER) preserving posterolateral approach to reduce dislocation after hip arthroplasty, especially in elderly patients. The present study was conducted to introduce SER preserving posterolateral approach and report the dislocation rate after HA via this approach in elderly patients with femoral neck fractures. METHODS: Between January 2015 and July 2019, 307 consecutive elderly patients aged over 70 years who underwent cementless bipolar HA for femoral neck fractures and were followed up for at least one year, were enrolled in this study. All surgeries were performed using the SER preserving posterolateral approach. The demographic and perioperative data were examined and the complications including dislocation were investigated. RESULTS: Mean operation time was 54.3 min, and mean estimated blood loss was 252.4 cc. The mean follow-up time was 22.1 months, HHS was 67.5 points at the final examination Dislocation following HA developed in only one patient (0.3%) with dementia during hospital stay, which was reduced closely with no subsequent recurrence. Periprosthetic femoral fracture occurred in two patients, which was treated with internal fixation in one patient and with stem revision in the other patient. There was no surgical site infection or periprosthetic infection as complications. CONCLUSION: The SER preserving technique in posterolateral approach effectively can be effective for reducing the dislocation after HA in elderly patients with femoral neck fracture. It can be encouraged in posterolateral approach for HA, especially in elderly patients under the risk of dislocation.


Assuntos
Artroplastia de Quadril , Fraturas do Colo Femoral , Hemiartroplastia , Fraturas Periprotéticas , Idoso , Artroplastia de Quadril/efeitos adversos , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/etiologia , Fraturas do Colo Femoral/cirurgia , Hemiartroplastia/efeitos adversos , Humanos , Fraturas Periprotéticas/cirurgia , Resultado do Tratamento
15.
Knee Surg Sports Traumatol Arthrosc ; 30(5): 1594-1604, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34264371

RESUMO

PURPOSE: To investigate the surgical outcomes of anatomical anterior cruciate ligament (ACL) reconstruction according to the graft isometry measured during surgery. METHODS: Electrical medical records of patients who underwent an arthroscopic ACL reconstruction through the transportal technique using hamstring tendon autograft between 2012 and 2016 were retrospectively reviewed. The patients were classified into two groups based on the graft length change throughout the knee range of motion measured just before graft fixation (Group 1, graft length change ≤ 2 mm; Group 2, graft length change > 2 mm). Comparative analyses, including a non-inferiority trial, were performed regarding the clinical scores, knee laxity, and radiographic parameters between the groups. RESULTS: A total of 67 patients were included in the study. The total change in the length of ACL graft throughout the knee range of motion was 1.4 ± 0.4 mm in Group 1 (range, 0.2-2.0 mm), and 3.0 ± 0.7 mm in Group 2 (range, 2.2-5.0 mm). Group 1 showed a relatively high (proximal) femoral tunnel and shallow (anterior) tibial tunnel compared to Group 2 (P < 0.001 and P = 0.028, respectively), but there were no apparent differences in the macroscopic view. There were no statistically significant differences in the clinical outcomes between groups at 2 years after surgery, which satisfied the non-inferiority criterion of Group 1 in terms of clinical scores and knee laxity compared to Group 2. CONCLUSION: The surgical outcomes of anatomical ACL reconstruction in patients with non-isometric ACL graft were not inferior in terms of clinical scores and knee laxity, compared to those with nearly-isometric ACL graft. The graft tunnel placement in the isometric position during anatomical ACL reconstruction, which is technically challenging in the clinical setting, is not a crucial factor in terms of clinical outcomes. LEVEL OF EVIDENCE: Level IV.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Tendões dos Músculos Isquiotibiais , Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Tendões dos Músculos Isquiotibiais/transplante , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
16.
PLoS One ; 16(7): e0253862, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34197561

RESUMO

A finite element analysis was performed to evaluate the stresses around nails and cortical bones in subtrochanteric (ST) fracture models fixed using short cephalomedullary nails (CMNs). A total 96 finite element models (FEMs) were simulated on a transverse ST fracture at eight levels with three different fracture gaps and two different distal locking screw configurations in both normal and osteoporotic bone. All FEMs were fixed using CMNs 200 mm in length. Two distal locking screws showed a wider safe range than 1 distal screw in both normal and osteoporotic bone at fracture gaps ≤ 3 mm. In normal bone FEMs fixed even with two distal locking screws, peak von Mises stresses (PVMSs) in cortical bone and nail constructs reached or exceeded 90% of the yield strength at fracture levels 50 mm and 0 and 50 mm, respectively, at all fracture gaps. In osteoporotic bone FEMs, PVMSs in cortical bone and nail constructs reached or exceeded 90% of the yield strength at fracture levels 50 mm and 0 and 50 mm, respectively, at a 1-mm fracture gap. However, at fracture gaps ≥ 2 mm, PVMSs in cortical bone reached or exceeded 90% of the yield strength at fracture levels ≥ 35 mm. PVMSs in nail showed the same results as 1-mm fracture gaps. PVMSs increased and safe range reduced, as the fracture gap increased. Short CMNs (200 mm in length) with two distal screws may be considered suitable for the fixation of ST transverse fractures at fracture levels 10 to 40 mm below the lesser trochanter in normal bone and 10 to 30 mm in osteoporotic bone, respectively, under the assumptions of anatomical reduction at fracture gap ≤ 3 mm. However, the fracture gap should be shortened to the minimum to reduce the risk of refracture and fixation failure, especially in osteoporotic fractures.


Assuntos
Pinos Ortopédicos , Osso Cortical/lesões , Fixação Intramedular de Fraturas/instrumentação , Fraturas do Quadril/cirurgia , Osteoporose/cirurgia , Fenômenos Biomecânicos , Parafusos Ósseos , Osso Cortical/patologia , Osso Cortical/cirurgia , Análise de Elementos Finitos , Fraturas do Quadril/etiologia , Fraturas do Quadril/patologia , Humanos , Osteoporose/complicações , Osteoporose/patologia
17.
Arthroscopy ; 37(9): 2903-2914.e1, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33887417

RESUMO

PURPOSE: To investigate the surgical outcomes of anterior cruciate ligament (ACL) reconstruction using a low-dose irradiated tibialis anterior allograft with a fixed-loop cortical suspension device for the femur based on the graft insertion length (GIL) in the femoral tunnel. METHODS: Between January 2010 and January 2018, the medical records of consecutive patients who underwent arthroscopic ACL reconstruction with a tibialis anterior allograft fixed with the EndoButton CL for the femur and who had at least 2 years of follow-up were retrospectively evaluated. Patients were classified into 3 groups based on the GIL in the femoral tunnel (group 1, GIL < 15 mm; group 2, GIL of 15-20 mm; and group 3, GIL > 20 mm), and their functional scores, knee laxity, and radiographic parameters were evaluated. RESULTS: A total of 91 patients were analyzed. There were no statistically significant differences in the functional scores and knee laxity between the 3 groups at 2 years postoperatively. However, significant differences were observed in tunnel widening at 1 year postoperatively in the femur (P = .045 for absolute value and P = .004 for relative value) and the tibia (P = .014 for absolute value and P = .012 for relative value), revealing that both the femoral and tibial tunnels widened as the GIL decreased. Additional linear regression analyses were performed to identify whether the GIL independently affects tunnel widening. Consequently, the femoral tunnel depth, tunnel diameter, and GIL were found to independently influence femoral tunnel widening (P = .008, P = .019, and P < .001, respectively), whereas the tunnel diameter and GIL affected tibial tunnel widening (P < .001 and P = .004, respectively). CONCLUSIONS: The GIL in the femoral tunnel during ACL reconstruction using a tibialis anterior allograft with a fixed-loop cortical suspension device for the femur has no significant association with the postoperative functional outcomes and knee laxity, but it has a negative correlation with tunnel widening in the femur and the tibia. LEVEL OF EVIDENCE: Level III, retrospective cohort study.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Aloenxertos , Lesões do Ligamento Cruzado Anterior/cirurgia , Fêmur/cirurgia , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Estudos Retrospectivos , Tíbia/cirurgia , Resultado do Tratamento
18.
Bone Joint Res ; 10(4): 250-258, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33820433

RESUMO

AIMS: There are concerns regarding initial stability and early periprosthetic fractures in cementless hip arthroplasty using short stems. This study aimed to investigate stress on the cortical bone around the stem and micromotions between the stem and cortical bone according to femoral stem length and positioning. METHODS: In total, 12 femoral finite element models (FEMs) were constructed and tested in walking and stair-climbing. Femoral stems of three different lengths and two different positions were simulated, assuming press-fit fixation within each FEM. Stress on the cortical bone and micromotions between the stem and bone were measured in each condition. RESULTS: Stress concentration was observed on the medial and lateral interfaces between the cortical bone and stem. With neutral stem insertion, mean stress over a region of interest was greater at the medial than lateral interface regardless of stem length, which increased as the stem shortened. Mean stress increased in the varus-inserted stems compared to the stems inserted neutrally, especially at the lateral interface in contact with the stem tip. The maximum stress was observed at the lateral interface in a varus-inserted short stem. All mean stresses were greater in stair-climbing condition than walking. Each micromotion was also greater in shorter stems and varus-inserted stems, and in stair-climbing condition. CONCLUSION: The stem should be inserted neutrally and stair-climbing movement should be avoided in the early postoperative period, in order to preserve early stability and reduce the possibility of thigh pain, especially when using a shorter stem. Cite this article: Bone Joint Res 2021;10(4):250-258.

19.
Sci Rep ; 11(1): 5539, 2021 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-33692436

RESUMO

This study aimed to evaluate (1) the overall reasons for first revision in CoC THAs; (2) whether the reasons for revision differ between third-generation and fourth-generation CoC THAs; and (3) the specific factors associated with bearing-related problems as the reason for revision. We retrospectively reviewed 2045 patients (2194 hips) who underwent first revision THA between 2004 and 2013, among which 146 hips with CoC bearings underwent revision. There were 92 hips with third-generation ceramic bearings and 54 hips with fourth-generation ceramic bearings. The major reasons for CoC THA revisions were ceramic fracture and loosening of the cup or stem. When ceramic fracture, squeaking, incorrect ceramic insertion, and unexplained pain were defined as directly related or potentially related to ceramic use, 28.8% (42/146) of CoC revisions were associated with bearing-related problems. Among the third-generation ceramic bearings, revision was performed in 41.3% (38/92) of cases owing to bearing-related problems whereas revisions were performed for only 7.4% (4/54) of cases with fourth-generation ceramic bearings owing to bearing-related problems (p < 0.001). Younger age, lower American Society of Anesthesiologists (ASA) grade, and preoperative diagnosis of osteonecrosis were factors related to CoC THA revisions due to bearing-related problems.


Assuntos
Artroplastia de Quadril/efeitos adversos , Cerâmica/efeitos adversos , Prótese de Quadril/efeitos adversos , Osteonecrose/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Falha de Prótese , Sistema de Registros , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteonecrose/etiologia , Fatores de Risco , Fatores de Tempo
20.
Diagnostics (Basel) ; 11(2)2021 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-33562261

RESUMO

High tibial osteotomy (HTO) is an effective alternative for medial compartmental knee osteoarthritis (OA). Circulating microRNAs (miRNAs) are known to serve as OA-related biomarkers. The present study investigated the differential expression of serum miRNAs before and after HTO to identify potential miRNAs as prognostic biomarkers. miRNA-polymerase chain reaction (PCR) arrays were used to screen for miRNAs in the serum at preoperative and 6-month postoperative time points from six patients, and the differentially expressed miRNAs identified in the profiling stage were validated using real-time PCR at post-operative months 6 and 18 in 27 other HTO-treated patients. Among 84 miRNAs involved in the inflammatory process, three (miR-19b-3p, miR-29c-3p, and miR-424-5p) showed differential expression patterns in the profiling stage (p = 0.011, 0.015, and 0.021, respectively). Levels of these three and four other miRNAs (miR-140-3p, miR-454-3p, miR-let-7e-5p, and miR-885-5p) known to be related to OA progression were evaluated in the serum of 27 patients. Only four miRNAs (miR-19b-3p, miR-140-3p, miR-454-3p, and miR-let-7e-5p) were significantly upregulated at postoperative month 6 (p = 0.003, 0.005, 0.004, and 0.004, respectively), and only miR-140-3p was significantly upregulated up to 18 months after operation (p = 0.003). Together, this study reveals the significantly upregulated serum miRNAs after HTO as potential prognostic biomarkers; however, further studies are warranted to elucidate their clinical implications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...